When only one current output is required, Output 1 should be selected
(Pin 4)
5.3 Switching output
All pyrometers of the PA Series feature two switching outputs which can
be configured as digital outputs or digital inputs. The open collector out-
puts allow for a voltage of +24 V DC. The maximum current of each open
collector output is 30 mA.
See Chapter 7.2 for more information configuration.
6 Getting Started
6.1 General installation tips
Install the pyrometer in a location where it will not be unnecessarily ex-
posed to smoke, ambient heat or water vapour.
A false reading (too low) will be displayed when the pyrometer lens is
dirty. Therefore always ensure that the lens is clean.
red
VK 02/A
Digital input 1
blue
brown
Digital input 2
Ground
PLC
+24 V