3.4 Dryer
Dryer is installed in the refrigeration circuit to remove any moisture which may have
entered the circuit. It is filled with strongly hygroscopic granules.
Fig.4: Dryer structure
1 Drying agent
2 Coarse sieve
3 Fine sieve
Foreign objects can be caught in the sieve so that they cannot block the capillary tube.
Dryer must be replaced every time work is done on the refrigeration circuit. It should al-
ways be mounted vertically.
There are three dryers available that can be used for repairs depending on the config-
uration / position of components in appliance machine room.
Fig.5: Dryers released by the product area available for repairs
1 [00093110]
2 [00643484]
3 [00649378]
Design and function