2.3 Product-specific safety information
2.3.1 Refrigeration and freezer appliances
Risk of burns caused by refrigerants!
¡ Wear protective gloves and goggles.
Explosion hazard due to refrigerants!
¡ Do not solder pipe connections, only use Lokring connections.
¡ Do not press any electrical switches.Do not press any electrical switches.
¡ Keep clear of thermal appliances.
¡ Extinguish / keep clear of open flames.
¡ Ensure that room is well ventilated.
2.4 Measures after each repair
If the appliance is functional:
¡ Check according to VDE 0701 or country-specific regulations.
¡ Check external appearance, function and tightness.
¡ Document repair work, measured values and functional reliability.
If the appliance is not functional:
¡ Identify the appliance as “not functionally reliable”.
¡ Warn customers of commissioning and notify them in writing .
Safety