Fault Possible cause Troubleshooting
Icing up / condensation on side panels Humidity above 80 %, insufficient ventilation between
the side panels, particularly in side-by side appliances
(refrigerator and freezer are set up together)
Required tools:
Insulation mat non flammable [20000786]
1. Install insulation mat (1).
2. Cut insulation mat (2).
Foaming failure due to trapped air in the separating
wall between refrigerator and freezer compartment
Replace appliance.
Build-up of ice at a single point Drain gutter or hole for condensation water blocked or
covered
Wipe back panel with detergent solution.
Fault Diagnosis
2020-08-03_58300000002379_ara_en_p Copyright by BSH Hausgeräte GmbH Page 42of73