Fault Possible cause Troubleshooting
Injection noises on the evaporator High flow rate of refrigerant / Capillary tube bent Required tools:
Noise damping
mass
Butyl, outside use [00153737]
For refrigerator compartment aluminum evaporators, the capillary
tube is not accessible!
1. For freezer compartment wire tube evaporators: bend capillary tube
straight.
2. Cover the injection point with damping mass.
Abnormal noises Appliance not leveled
1. Align appliance flat with a spirit level.
2. Adjust threaded feet or place something underneath.
Appliance positioned against other objects
Move appliance away from adjacent furniture.
Removable parts inside appliance compartment
loosed or jammed
1. Check removable parts.
2. Replace defective removable parts.
Bottles or containers touching each other
Separate bottles or containers.