Fault Possible cause Troubleshooting
Injection noises on the evaporator High flow rate of refrigerant / Capillary tube bent Required tools:
Noise damping
mass
Butyl, outside use [00153737]
For refrigerator compartment aluminum evaporators, the capillary
tube is not accessible!
1. For freezer compartment wire tube evaporators: bend capillary tube
straight.
2. Cover the injection point with damping mass.
Abnormal noises Appliance not leveled
1. Align appliance flat with a spirit level.
2. Adjust threaded feet or place something underneath.
Appliance positioned against other objects
▶
Move appliance away from adjacent furniture.
Removable parts inside appliance compartment
loosed or jammed
1. Check removable parts.
2. Replace defective removable parts.
Bottles or containers touching each other
▶
Separate bottles or containers.
Fault Diagnosis