1. Place data logger in geometric center of the compartment.
2. Inform the customer that the appliance door should be opened as infrequently as
possible and only little amount of fresh products should placed in the appliance
during the measurement.
3. Leave data logger inside appliance for a longer period (at least 24 h).
4. Evaluate the data from data logger.
6.1.2 Temperature measurement without data logger
Required tools:
Thermometer High-precision fast-response thermo-
meter GTH 1170
[00341176]
Prerequisite:
Appliance is in equilibrium during measurement.
1. Place glass of water in geometric center.
2. Inform the customer that the appliance door should be opened as infrequently as
possible and only little amount of fresh products should placed in the appliance
during the measurement.
3. Leave glass of water inside appliance for a longer period (at least 24 h).
4. Perform temperature measurement in the water.
Measuring technology