EasyManua.ls Logo

Siemens KG39EAI43 - Evacuating refrigeration circuit (R600 a)

Siemens KG39EAI43
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vacuum pump R600a, Refco RL-4, Weight: 5.65kg,
Output: 65l/min (2.3cfm), Vacuum ex
works: 15micron, Engine: 0.19KW,
2400rpm, Connections: 1⁄4" SAE +
3⁄8" SAE
[00340790]
Pressure gauge and tubes set R600a, double pressure gauge, tubes
red, yellow, blue length 930mm, tube
red length 300mm
[00340401]
Fig.19: Filler tools for R600a refrigerant
1 Connection for tormeter
2 Intake side valve / blue
3 Vacuum-pressure gauge / blue
4 Tormeter
5 Valve to shut off the tormeter / yellow / for vacuum pump
6 Vacuum pump
7 Filler valve / black / for refrigerant
8 Connecting hose / yellow / for vacuum pump
9 Connecting hose / red / for service valve attached on refrigerant bottle
10 Pressure side valve / red
11 Connecting hose / red / for service pipe of the dryer (pressure side)
12 Connecting hose / blue / for service pipe of the compressor (suction side)
Prerequisite:
Dryer and compressor (if required) are replaced.→Page 60
Refrigerant cartridge is prepared.→Page 61
All filling station valves are closed.
1. 1. Connect the blue hose to for the intake side to the compressor service con-
nection (1).
2. Connect the red hose for the pressure side to the dryer service connection (2).
2. Connect yellow hose to the vacuum pump.
Repair
2020-08-03_58300000002379_ara_en_p Copyright by BSH Hausgeräte GmbH Page62of73