7ML19981FB05 MultiRanger 100/200 – INSTRUCTION MANUAL Page 219
mmmmm
Parameters
Reading Measurements by Operation
P921 Material Measurement
The distance in Units (P005) or % of Span (P007) between Empty (P006) and the
monitored surface.
P922 Space Measurement
The distance between the monitored surface and Span (P007).
P923 Distance Measurement
The distance between the monitored surface and the transducer face.
P001 P050 = 0 P050 0
0 – OFF - - - - - - - -
1 – Level P921 P924
2 – Space P922 100% - P924
3 – Distance P927 P927
4 – Difference [MR 200] P921 (indexed) P921 (indexed)
5 – Average [MR 200] P921 (indexed) P921 (indexed)
6 – OCM [MR 200] P925 P925
7 – Pump Totalizer [MR 200] P924 P924
Primary Index Level
Values Range: -999 to 9999
Related
P005 Units
P006 Empty
P007 Span
Primary Index Transducer
Values Range: 0.000 to 9999
Related P007 Span
Primary Index Transducer
Values Range: 0.000 to 9999