,QWHUQDWLRQDO(QJOLVK (1*,1((5,1*,1)250$7,21
MICROMASTER 420 Reference Manual
Issue A1
7
)LJXUHV
Figure 2-1 Current Limit Interaction .........................................................................................................8
Figure 2-2 PTC Resistor Connections ..................................................................................................10
Figure 2-3 Boost Level...........................................................................................................................11
Figure 2-4 Quick response with overshoot: P2280 = 0.30; P2285 = 0.03 s..........................................14
Figure 2-5 Quick response with overshoot, but instability: P2280 = 0.55; P2285 = 0.03 s ....................15
Figure 2-6 Damped response: P2280 = 0.20; P2285 = 0.15 s...............................................................15
Figure 2-7 Response to 5 Hz step: L = 100 ms .....................................................................................16
Figure 2-8 Response to 5 Hz step: T = 700 ms .....................................................................................17
Figure 2-9 Step Response in PI control with P2280 = 9.84 and P2285 = 0.30......................................17
Figure 2-10 PI Basic Block Diagram........................................................................................................19
Figure 2-11 Frequency Ramp Down........................................................................................................20
Figure 2-12 DC Braking...........................................................................................................................20
Figure 2-13 Compound Braking...............................................................................................................21
Figure 2-14 Derating with Temperature...................................................................................................22
Figure 2-15 Derating with Altitude............................................................................................................24
Figure 2-16 Power Losses.......................................................................................................................38
7DEOHV
Table 2-1 Current Limit and Overload.....................................................................................................8
Table 2-2 Measured Current Monitoring Accuracy .................................................................................9
Table 2-3 Trip Levels............................................................................................................................11
Table 2-4 Maximum Cable Lengths......................................................................................................23
Table 2-5 Derating with Switching Frequencies....................................................................................25
Table 2-6 Cubicle Calculations.............................................................................................................26
Table 2-7 BiCo Connections (r0019 to r0054) ......................................................................................31
Table 2-8 BiCo Connections (r0055 to r1119) ......................................................................................32
Table 2-9 BiCo Connections (r1170 to r2050) ......................................................................................33
Table 2-10 BiCo connections (r2053 to r2294).......................................................................................34
Table 2-11 Acoustic Test Results...........................................................................................................35
Table 2-12 Single Phase 230V Connection............................................................................................36
Table 2-13 Three Phase 230V Connection.............................................................................................36
Table 2-14 Three Phase 400V Connection.............................................................................................37

Table of Contents

Other manuals for Siemens MICROMASTER 420

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MICROMASTER 420 and is the answer not in the manual?

Siemens MICROMASTER 420 Specifications

General IconGeneral
Power Range0.12 kW to 11 kW
Output Voltage0 to input voltage
Input Frequency47 Hz to 63 Hz
Output Frequency0 Hz to 650 Hz
Overload Capacity150% for 60 seconds
Enclosure RatingIP20
Input Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)
Control TypeV/f control
BrakingOptional braking module
Protection FeaturesOvercurrent, overvoltage, undervoltage, overload, short circuit, ground fault
CoolingAir-cooled
Ambient Temperature-10 °C to +50 °C
Communication InterfacesUSS protocol