7ML19985FM01 MFA 4p – INSTRUCTION MANUAL Page 23
mmmmm
Applications
Applications
Bucket Elevators
For chain and sprocket drive
elevators, place the probe so that
the gap between the bucket and the
probe does not exceed 102 mm (4").
To prevent damage to the probe from
eccentric bucket motion, ensure that
the gap is not less than 12.5 mm
(0.5") in the worst condition.
Preferred location for belt-driven elevators
with ferrous bucket spacing greater than
76 mm (3"), and non-ferrous buckets with
ferrous bolts
.
For ferrous buckets with spacings less than
76 mm (3") locate probe on the front of the leg.
probe (see
Figure A)
preferred
location for
chain and
sprocket
drive
elevators.
down leg
probe (see
Figure A)
knee and
housing
work floor
102 mm (4")
For elevators with ferrous walls,
cut 88 mm to 95 mm (3.5" to 3.75")
hole in the elevator wall. Any
position from A to C may be used
to maintain the gap.
Figure A
mounting
flange and
locknut
elevator
wall
95 mm
(3.75")
probe
AB C
7ML19985FM01.book Page 23 Wednesday, May 21, 2008 2:17 PM

Other manuals for Siemens milltronics MFA 4P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens milltronics MFA 4P and is the answer not in the manual?

Siemens milltronics MFA 4P Specifications

General IconGeneral
BrandSiemens
Modelmilltronics MFA 4P
CategorySecurity System
LanguageEnglish

Related product manuals