34 Kienzle MTCO 1324
Trouble shooting
Only after having remedied the error cause,
e.g. in case of an operating error, will the
message automatically be deleted.
Updating the chart carrier
 Open the drawer and remove both
charts.
 Close the drawer again.
½ The MTCO will automatically update
the time of the chart carrier, and the
error symbol and the time will then
stop to flash.
 Open the drawer and insert new charts if
necessary. The MTCO 1324 will be ready
for use again.
Displayed messages Code Meaning / measure
9061
9062
9063
= Error in recording system
(The MTCO will record these errors on the chart,
see page 39.)
9430
= Error at "B7" v-pulse output
A411
= Disconnection towards indicating instrument
A423
A822
=
=
Error during pulse generator communication
Error in pulse generator key / serial number /
signal
(The MTCO will record these errors on the chart,
see page 39.)
A400
=Power loss
(Error code cannot be found in the error memory.
The MTCO will record a power loss on the chart,
see page 39.)
In case one of the messages is shown
repeatedly, immediately consult a
Siemens VDO service partner!