7ML19985QD82 MultiRanger – MISE EN SERVICE SIMPLIFIEE Page FR-i
mmmmm
Appendice A
Appendice A : Entrée de conduit pour
applications Classe 1, Div 2
2365031400
S. NGUYEN
PETERBOROUGH
14/ AUG / 02
ULTRASONICS
FOR CONSTRUCTION
0
T. ADA M
R. CLYSDALE
1 : 1
1
2
NONE
HINGED 6 X 9 ENCLOSURE WITH
CONDUIT ENTREES & ASSEMBLE
FOR CLASS 1 DIV 2 APPLICATIONS
23650314
0
RPC
SN
AUG
14/02
6.33
1.688
9.46
0.94
0.875
1.50
2.62
3.25
4.625
DRILL FOR 1/2”
CONDUIT HUBS
DRILL FOR 3/4”
CONDUIT HUB
NOTES:
1) USE ONLY CONDUIT HUBS CERTIFIED / APPROVED AS TYPE 4X.
2) NON METALLIC ENCLOSURE DOES NOT PROVIDE GROUNDING BETWEEN CONDUIT CONNECTIONS.
USE GROUNDING TYPE BUSHINGS AND JUMPER WIRES.
3) DIMENSIONS INCHES
WARNING
: – SUBSTITUTION OF COMPONENTS MAY IMPAIR
SUITIBILITY FOR CLASS I, DIVISION 2
EXPLOSION HAZARD