Appendix
A.2 Electromagnetic compatibility
Power Module PM330
Hardware Installation Manual, 12/2018, A5E32844552B AF
117
A.1.4
Certificates
Downloading certificates
You can find the certificates in the Internet here: Certificates
(https://support.industry.siemens.com/cs/ww/en/ps/13218/cert).
A.2
Electromagnetic compatibility
The SINAMICS G120 drives have been tested in accordance with the EMC product standard
EN 61800-3:2004.
For precise data, refer to the declaration conformity
A.2.1
Definition of the EMC Environment and Categories
Classification of EMC behavior
The EMC environment and categories are defined in the EMC Product Standard
EN 61800-3:2004., as follows:
Environments
First Environment
An environment that includes domestic premises and establishments that are connected
directly to a public low-voltage line supply without the use of an intermediate transformer.
Example: houses, apartments, commercial premises or offices in a residential building.
Second environment
An environment that includes all other establishments which are not connected directly to a
public low-voltage line supply.
Example: industrial and technical areas of buildings fed from a dedicated transformer.