EasyManua.ls Logo

Siemens PM330 - Page 81

Siemens PM330
150 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service and maintenance
5.4 Replacing additional components
Power Module PM330
Hardware Installation Manual, 12/2018, A5E32844552B AF
79
Note
Carefully insert the plug connections and ensure that they are secu
re.
Additional removal steps for the outer current transformer
Before removing the two outer current transformers, the subsequent removal steps must be
performed to gain access to the screws.
Figure 5-9 SINAMICS G120P current transformer 2
Current transformer, left:
1. Release interlock
of the left-hand housing flap, which allows you to access screws
to be removed.
2. Then follow the removal steps for the middle current transformer, see above.
Current transformer, right:
1. Remove nuts
and screws and of the DCP busbar and the DCN busbar .
2. Remove the DCP busbar
and DCN busbar .
3. Then follow the removal steps for the middle current transformer, see above.

Table of Contents