Operating the thermostat on the device
Advanced settings
6
34 | 59 A6V10877569_en--_e
No.
Application
settings
Descriptions
Factory
settings
Range Dependencies
35. Heating
device
electrical
load
The electrical load of
your connected
heating device. It is
recommended to
enter the real
electrical load of your
heating device.
Otherwise the
temperature offset
algorithm at the
background may not
be accurate.
0 A (2 A if
you’ve
selected
the
equipmen
t type as
Electric
floor
heating,
Fan with
electric
heating or
Electric
radiator.
0…5 A
36. Q22/Q24
electrical
load
The electrical load of
connected outputs
2 A 0…5 A Displays only if
you’ve
configured an
output.
37.
Off/protection
configuration
Configures whether
the thermostat goes
to the protection
mode or completely
turns off in “OFF”
mode.
Protection Off
Protection
N/A
Other settings