Table of contents
PAC RS485
Manual, 02/2008, A5E02091800B-01
5
Tables
Table 1-1
Contacts in your region - worldwide...............................................................................................9
Table 1-2 Online service and support ............................................................................................................9
Table 1-3 Technical Support ........................................................................................................................10
Table 5-1 Structure of the message frame...................................................................................................29
Table 5-2 Supported function codes ............................................................................................................31
Table 5-3 MODBUS exception codes ..........................................................................................................33
Table 5-4 Available measured variables......................................................................................................34
Table 5-5 Structure - Status of the digital inputs and status of the digital outputs.......................................38
Table 5-6 Modbus offset 205, tab 2: Structure device status and device diagnostics.................................38
Table 5-7 Modbus Offset 203, Register 2: Limit Violations..........................................................................39
Table 5-8 Status parameters........................................................................................................................39
Table 5-9 Settings parameters.....................................................................................................................40
Table 5-10 Settings parameter for the digital input ........................................................................................41
Table 5-11 Settings parameter for the digital output......................................................................................41
Table 5-12 Settings parameter for language, phase labels and universal counters source..........................42
Table 5-13 Settings parameter for the display ...............................................................................................43
Table 5-14 Settings parameter for limit value 0 .............................................................................................43
Table 5-15 Settings parameter for limit value 1 .............................................................................................44
Table 5-16 Settings parameter for limit value 2 .............................................................................................45
Table 5-17 Settings parameter for limit value 3 .............................................................................................47
Table 5-18 Settings parameter for limit value 4 .............................................................................................48
Table 5-19 Settings parameter for limit value 5 .............................................................................................49
Table 5-20 Command parameters .................................................................................................................51
Table 5-21 Communication parameters.........................................................................................................52
Table 5-22 I&M 0 parameter of the SENTRON PAC Power Monitoring Device with the function codes
0x03 and 0x04 .............................................................................................................................54
Table 5-23 I&M 1-4 parameters with the function codes 0x03, 0x04 and 0x10.............................................54
Table 5-24 I&M 0 parameter of the module in slot 1 with the function codes 0x03 and 0x04 .......................54
Table 5-25 MODBUS standard device identification parameters ..................................................................55
Table 5-26 Parameters supported by the broadcast commands...................................................................56
Table 6-1 Factory settings............................................................................................................................57
Table 6-2 Structure of the setting versions ..................................................................................................59
Table 6-3 Setting options .............................................................................................................................60
Table 6-4 Performance calculation ..............................................................................................................60
Table 8-1 Fault and status indication by the LED ........................................................................................64
Table 10-1 The device meets the following standards...................................................................................67

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SENTRON PAC RS485 and is the answer not in the manual?

Siemens SENTRON PAC RS485 Specifications

General IconGeneral
Communication InterfaceRS485
ProtocolModbus RTU
DisplayLCD
MountingDIN Rail
Device TypePower Monitoring Device
SeriesSENTRON PAC
Operating Temperature-10 °C to +55 °C
Storage Temperature-25 °C to +70 °C
Relative Humidity5 % to 95 % (non-condensing)
WeightApprox. 0.3 kg
Frequency Measurement Range45 Hz to 65 Hz
Protection ClassIP20