Configuring/address space
4.4 Parameter
Technology module TM ECC 2xPWM ST (6FE1242-6TM10-0BB1)
34 Manual, 04/2018, A5E42681298B-AA
Table 4- 4 Configurable parameters and their defaults
ECC standard
a)
(
ar
harging)
• IEC 61851-1
• SAE J1772
IEC 61851-1 No
Charging outlet active
• Yes
• No
Yes No
Integrated charging
cable
• Yes
• No
No No
Cable locking
• No locking
• External (via PII)
• Pole reversal pulse
800 ms
• Polarity reversal
permanent
• Open collector
Pole reversal pulse
800 ms
No
Cable locking
feedback
b)
• No feedback
• Internal module DI
• External (via PIQ)
Internal module DI No
Contactor feedback
b)
• No feedback
• Internal module DI
• External (via PIQ)
External (via PIQ) No
Maximum charging
6 .. 80 13 No
DI input voltage
• 12 V input
c)
• 24 V input
d)
24 V input No
If "SAE J1772" is selected in the hardware configuration, the parameter "Integrated charging
cable" is automatically set to "Yes". Electromotive locking is not possible in this case.
Any PP resistor possibly plugged in is not evaluated! The maximum charging current is limited
here by the configuration of the module in TIA and by the "Maximum permissible charging current"
parameter or, when using the FC4100, by the "MaxCurr" parameter.
Any potential PP conductor of the charging cable must not be connected to the PP terminal, oth-
erwise an error is output.
Note that both feedbacks cannot be set to the internal module DI at the same time.
Low level: 0 ..2.5 V; High level: 5.5 .. 12 V
d)
Low level: 0 ..5 V; High level: 11 .. 24 V