1-4
OP27,
OP37 Equipment Manual
Release 05/99
Messages
are displayed on the OP in plain text. The message text may also
contain current process values. Incoming messages are stored in a message
buf
fer together with their date and time.
Event messages
provide information and operating notes on current processes or machine
states, for example
Motor running at 3000 revs.
Alarm
messages
provide information on critical machine states, for example
Motor speed too high.
Alarm
messages must be acknowledged on account of their ur
gency.
Messages are classified as event messages or alarm messages during configura
-
tion.
All message events can be additionally recorded by being printed out in online
mode on a connected printer
. Messages which have accumulated in the event
and alarm buf
fers can also be printed out.
It is possible to print the current status of a screen by pressing
PRINT
SCREEN. It
is possible to configure a function which enables up to 20 screens to be printed
simultaneously.
T
exts identify individual parts of the screen in order to be able to assign the
fields displayed to the process.
Help texts represent additional information and notes for the operator which
can be configured in respect of the screens, input fields and messages. The help
text relating to an alarm message may display information on the cause of a
malfunction and how to clear it.
Complete machine data records can be stored as recipes in the OP
. A recipe
defines the data structure in a configuration. Data is assigned to the configured
structure on the OP
.
The purpose of recipes is to transfer several items of data collectively to the
PLC. In this respect, it is immaterial whether actual recipes, specifications of
quantities, distances to be traversed or temperature variations are involved.
Message texts, texts in screens, help texts and system messages can be stored
in three languages simultaneously in the OP and selected online.
The password protection feature prevents unauthorized operation of the OP
.
Dif
ferent passwords can be assigned to dif
ferent users or user groups, thus
authorizing or prohibiting access to specific control functions by assigning
dif
ferent password levels.
Messages
Recording
Print
Texts
Help texts
Recipe
Multiple languages
Password
protection
Product Description
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simatic hmi op27 and is the answer not in the manual?

Siemens simatic hmi op27 Specifications

General IconGeneral
BrandSiemens
Modelsimatic hmi op27
CategoryControl Panel
LanguageEnglish

Related product manuals