Technical specifications
8.5 Technical specifications
SIMATIC IPC427D
Operating Instructions, 05/2017, A5E31347215-AB
119
Relative humidity
- During operation
- During storage/shipping
tested to IEC 60068-2-78, IEC 60068-2-30
5% to 80% at 25° C (no condensation)
5% to 95% at 25° C (no condensation)
Barometric pressure
- During operation
- During storage/shipping
1080 to 795 hPa
(corresponds to an altitude of -1000 m to 2000 m)
1080 to 660 hPa
(corresponds to an altitude of -1000 m to 3500 m)
Mechanical conditions
Vibration
Tested to DIN IEC 60068-2-6
- During operation with CFast card or SSD:
5 to 9 Hz: 3.5 mm
9 to 500 Hz: 9.8 m/s2
with hard disk and wall installation:
10 to 58 Hz: 0.0375 mm
58 to 200 Hz: 4.9 m/s2
with hard disk and DIN rail mounting or vertical installation:
excitation not allowed
- During storage/shipping 5 to 9 Hz: 3.5 mm
9 to 500 Hz: 9.8 m/s2
Resistance to shock
Tested to DIN IEC 60068-2-27
- During operation without hard disk drive: 150 m/s
2
, 11 ms;
with hard disk drive: 50 m/s
2
, 30 ms
- During storage/shipping
250 m/s
2
, 6 ms