Technical specifications
8.7 BIOS description
SIMATIC IPC427D
Operating Instructions, 05/2017, A5E31347215-AB
155
"AMT Configuration" submenu
Entry
Meaning
Manageability Feature Selection
Enable and disable all AMT features.
SOL/IDER/KVM
Enable and disable the features SOL, IDE redirection, KVM.
User Consent User consent settings. Forces the following additional security
behavior: When a user attempts to establish a KVM connection
remotely, a six-figure number is displayed on the AMT PC. The
remote user must enter this number on the help desk PC before
the KVM connection can be opened.
Password Policy Password policy that specifies the conditions under which the
password can be changed from a remote location.
Network Setup Network settings, for example DHCP, IP address, host name,
domain name.
Activate Network Access Activates the network interface. This menu entry only exists if
the network is not activated.
Unconfigure Network Access Deactivates the network interface and resets the network set-
tings to their default values.
Remote Setup And Configuration
Displays the current provisioning settings.
Power Control Specifies the power states S0, S3, S4 of the computer in which
the ME is activated.