Technical specifications
9.5 Hardware descriptions
SIMATIC IPC477E PRO
134 Operating Instructions, 08/2017, A5E39912462-AA
9.5.3.3
Watchdog enable register (read/write address 062h)
Meaning of the bits
Watchdog enable register (r/w address 062h)
Bit
Meaning of the bits
7
6
5
4
3
2
1
0
Watchdog enable bit (WDE)
0 Watchdog circuit disabled
1
Watchdog circuit enabled
Watchdog Mode
0
Standard
1
Macro
Reserved
0
Reserved
1
Scaler watchdog time (Normal/Macro)
0
0
0
94 ms / 2 s (default)
0
0
1
210 ms / 4 s
0
1
0
340 ms / 6 s
0
1
1
460 ms / 8 s
1
0
0
590 ms / 16 s
1
0
1
710 ms / 32 s
1
1
0
840 ms / 48 s
1
1
1
960 ms / 64 s
Trigger red Watchdog LED
0
Red LED (WD) off
1 Red LED (WD) on
Watchdog error / Display and reset
0 WD inactive
1 WD triggered
Reset LED after watchdog alarm
(Bit 7 = write 1)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC477E PRO and is the answer not in the manual?

Siemens SIMATIC IPC477E PRO Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC477E PRO
CategoryIndustrial PC
LanguageEnglish

Related product manuals