Operating the device and device functions
6.4 Extended device functions
SIMATIC IPC477E PRO
64 Operating Instructions, 08/2017, A5E39912462-AA
6.4.1.2
Temperature monitoring/display
Three temperature sensors monitor the temperature of the device at several positions:
Processor temperature
Temperature close to the RAM ICs/chips
Temperature in proximity of the air inlet
A temperature error is triggered under these circumstances:
The configured low threshold for the temperature has been violated.
The configured high threshold for the temperature has been violated.
A temperature error causes the following reaction:
Reaction
Option
The DiagBase or DiagMonitor software alerts the user.
None
The temperature error is retained in memory until temperatures have fallen below the
thresholds and it is reset by one of the following measures:
Acknowledgment of the error message by the monitoring software
Restart of the device
6.4.1.3
Watchdog (WD)
Configuration
You configure the watchdog with the DiagBase or DiagMonitor software.
Function
The watchdog is able to monitor system runtime and informs the user about the different
reactions that are triggered if the system does not respond to the watchdog within the
specified monitoring time.
A watchdog alarm is retained after a restart and is reset and logged by the DiagBase or
DiagMonitor software. The watchdog configuration is retained in the process.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC477E PRO and is the answer not in the manual?

Siemens SIMATIC IPC477E PRO Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC477E PRO
CategoryIndustrial PC
LanguageEnglish

Related product manuals