03/2013 3 Setting up functions
3.4 Fault services
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3-149
3.4.12 Trigger on synchronization
With a trigger to the set synchronization, it is possible to check and also respond if
a machine is no longer logged in to the server and is therefore not supplying any
data.
Fig. 3-38: Triggers on synchronization
Function Description Type
Name Name of the trigger; can be entered by the user. If
the field remains empty or is deleted, the system
will generate a name.
If the name already exists, a consecutive number
is automatically added in parentheses.
If the name is too long, the number added can
only be seen in a tooltip.
DISPLAY
INPUT
(max. 100
characters,
all characters
are
permissible)
Delay Delay time in seconds after a missing
synchronization, in which the trigger should still
not respond.
The value must be less than the interval time
specified below.
Interval
between
triggers
This time should approximately correspond to the
set synchronization time.
DISPLAY
INPUT
(max.
10-digit)