EasyManua.ls Logo

Siemens Simatic S7-300 - Trigger on Control Monitor Script Error

Siemens Simatic S7-300
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Setting up functions 03/2013
3.4 Fault services
© Siemens AG 2006-2013 All Rights Reserved
3-150 SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3.4.13 Trigger on control monitor script error
To be able to automatically check malfunctions in the configuration for defective
control monitors, you can set up the trigger on "control monitor script error".
This function is for troubleshooting only.
Each configured action, that does not provide the expected result, is signaled as a
case. This can be an access to a non-existent variable or any other incomplete
configurations.
Fig. 3-39: Trigger on script error
Function Description Type
Name Name of the trigger; can be entered by the user.
If the field remains empty or is deleted, the
system will generate a name.
If the name already exists, a consecutive
number is automatically added in parentheses.
If the name is too long, the number added can
only be seen in a tooltip.
DISPLAY
INPUT
(max. 100
characters,
all characters
are
permissible)
Log level Scripts can be monitored on
- Normal error
- Information
- Warning
- Critical error
DISPLAY
SELECTION

Table of Contents

Other manuals for Siemens Simatic S7-300

Related product manuals