3 Setting up functions 03/2013
3.4 Fault Services
© Siemens AG 2006-2013 All Rights Reserved
3-178 SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
Function Description Type
Note:
If the remaining memory is insufficient for the current
definition of a trace, you can save the control monitor
inactively in the system. To make it possible to
activate it, you must free up memory by deactivating
one or more of the control monitors.
Remaining
performance
Shows how much performance is left in the PLC
cycle time for PLC triggers and PLC conditions.
See also Section: Fault services
DISPLAY
Configure PLC
settings
Since data blocks must be used in the PLC for the
configuration of PLC traces, these must be specified
in the PLC settings for SINUMERIK Integrate. If this
has not been done in the PLC settings or needs to be
checked again, it is possible to branch directly from
here for this purpose.
ACTION
"Icons" tab
PLC area
Absolute address
Shows the PLC variables with absolute addresses
(not symbolic addresses), which are to be recorded
in the trace, or for which additional programming can
be carried out.
The following selection can be made:
All: All PLC variables
E: Only PLC input variables
A: Only PLC output variables
M: Only flags
Z: Only counters
T: Only timers
DBs: Only data blocks
Note:
The PLC variables to be recorded are selected in the
same way as PLC triggers/conditions.
See also Section: Machine trigger on "PLC variable"
TAB DISPLAY
INPUT
S7 syntax
S7 formats
(max. 40
characters for
naming, all
characters are
permissible)
Absolute address
Display of the absolute address. DISPLAY
Comment Displays a comment for the absolute address. DISPLAY
Data type
Displays the data type. DISPLAY
Add icon
Absolute address
Entry of the address of a PLC variable via STEP 7
syntax.
INPUT
DISPLAY