03/2013 3 Setting up functions
3.4 Fault Services
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3-181
Description of the "Upload PLC data" function
Using a control monitor, the diagnostic action "Upload PLC data" permits some or
all PLC data blocks to be uploaded onto the server upon a trigger event.
Notice
The PLC data blocks are available on the server without a specific format.
Precisely one contiguous range of the same data block can be selected for
uploading for each control monitor.
To display the DB content, the data from the "Machine events" menu must be
exported and saved. A hexadecimal editor or byte-by-byte conversion in Excel is
recommended for visualization purposes.
With data block contents that change dynamically between the trigger event and
the completion of the transfer to the server, the limited bandwidth of the
communication channel to the PLC does not allow to guarantee that the states
are from a single cycle.
Fig. 3-63: Adding PLC data blocks
Fig. 3-64: PLC data block (details)
Function Description Type
Switch to the menu for configuring the data to be
uploaded.
If an existing configuration is changed, the
configured entries are displayed.
If added, the entry fields will not contain any
specifications.
ACTION
Deletes a PLC data block to be uploaded from the
list.
ACTION