Maintenance
9.3 Corrective maintenance
Standard motors SH 63 ... 355
Operating Instructions, 12/2018, A5E38483075A
107
Replacing bearings
Recommended interval after which bearings are to be replaced under normal operating
conditions:
Table 9- 4 Bearing replacement intervals
Ambient temperature
Principle of operation
Bearing replacement intervals
40 °C
Horizontal coupling operation
40 000 h
40 °C With axial and radial forces 20 000 h
Do not reuse bearings that have been removed.
Remove the dirty spent grease from the bearing shield.
Replace the existing grease with new grease.
Replace the shaft seals when the bearings are replaced.
Slightly grease the contact surfaces of the sealing lips.
Note
Special operating conditions
The operating hours are reduced, e.g.
When machines are vertically mounted.
High vibration and surge loads
Frequent reversing operation
Higher ambient temperatures.
High speeds etc.