Operation
8.1 Safety instructions for operation
Standard motors SH 63 ... 355
88 Operating Instructions, 12/2018, A5E38483075A
NOTICE
Risk of corrosion due to condensation
If the machine and/or ambient temperatures fluctuate, this can result in condensation inside
the machine.
If available, remove the drain plugs or drain screws to drain the water depending on the
ambient and operating conditions.
If available, re-attach the drain plugs or drain screws.
If the motor is equipped with drain plugs, then the water can drain away by itself.
Switching on the machine with anti-condensation heating (optional)
CAUTION
Machine overheating
Minor injury or material damage can occur if you do not observe the following:
If available, switch off the anti-condensation heating each time before switching on.
8.1.1 Safety instructions relating to ventilation and cooling
8.1.1.1 Safety instruction for forced ventilation (option)
Forced ventilation (optional): Type of cooling IC 416 in accordance with EN / IEC 60034-6
WARNING
Risk of burning
Operating the machine without external fan results in overheating. This may result in death,
personal injury and material damage.
Never commission the machine without an external fan.