EasyManua.ls Logo

Siemens SIMOTICS S-1FK2 - Page 161

Siemens SIMOTICS S-1FK2
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maximum permissible speed at converter n
max conv
The maximum permissible operating speed for operation at a converter is n
max conv
(e.g. limited
by withstand voltage, maximum frequency).
NDE
Non-drive end = Non-drive end of the motor
Static torque M
0
Thermal torque limit when the motor is at a standstill corresponding to the motor thermal class.
M
0
is always ≤ the rated torque M
N
.
Stall current I
0
Motor phase current to generate the particular stall torque (M
0
= k
T
I
0
). Speci󹪝cation of the RMS
value of a sinusoidal current.
Thermal time constant T
th
De󹪝nes the increase in the motor frame temperature when the motor load is suddenly increased
(step function) to the permissible S1 torque. The motor has reached 63% of its 󹪝nal temperature
after T
th
.
Moment of inertia J
Mot
Moment of inertia of rotating motor parts. J
Mot
= without brake, J
MotBr
= with brake.