The maximum torque that can be brie󹪞y achieved using this Motor Module is listed in the tables
of this manual as M
max inv
.
When con󹪝guring intermittent or overload operation, check whether a larger Motor Module
is required to provide the necessary peak current.
Tolerance data
The characteristic data listed in the data sheets are subject to a certain amount of scatter. The
following tolerances apply to the characteristic data:
Motor list data Typ. value Max. value
Current values I
0,
I
rated,
I
max
± 3 % ± 7.5 %
Torque values M
0,
M
rated,
M
max
± 3 % ± 7.5 %
Moment of inertia J
Mot
± 2 % ± 10 %
Tolerance data in the motor list data
The torque-speed characteristics speci󹪝ed in the following chapter relate to the nominal values
at operating temperature.
Technical data and characteristics
6.1 Explanations
1FK2 Synchronous Motors for SINAMICS S120
84 Con󹪝guration Manual, 02/2022, A5E46927724B AD