Technical data
4.1 Technical data D4x5
SIMOTION D4x5
60 Manual, 02/2012
PLC and motion control performance
Table 4- 5 Maximum number of axes and minimum cycle clocks for D4x5
Data SIMOTION D425 SIMOTION D435 SIMOTION
D445/D445-1
Maximum number of
axes
16 32 64
Minimum
PROFIBUS cycle clock
2 ms 1 ms 1 ms
Minimum PROFINET
send cycle clock
0.5 ms 0.5 ms 0.5 ms
Minimum position
control/interpolator
cycle clock
2.0 ms 1.0 ms 0.5 ms
Compared with SIMOTION D445, SIMOTION D445-1 offers an improvement in PLC and
motion control performance of approximately 30%, depending on the application.
Integrated drive control
Table 4- 6 Controls for integrated drives
Data SIMOTION D425 SIMOTION D435 SIMOTION
D445/D445-1
Max. number of axes for
integrated drive control
(servo/vector/
V
/
f
)
6 / 4 / 8 (alternative)
Drive control based
on SINAMICS S120
CU320, version V2.x
6 / 4 / 8 (alternative)
Drive control based on
SINAMICS S120
CU320, version V2.x
6 / 4 / 8 (alternative)
Drive control based on
SINAMICS S120
CU320, version V2.x