Start-Up 09.02
4-50 Siemens AG 6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit Operating Instructions
1
0
=
MI 1
MI 2
MI 3
MI 4
MI 5
MI 6
MII 1
MII 2
MII 3
MII 4
MII 5
MII 6
(0011)
P797
*1)
*1)
6005
6004
6003
0
0%
P486 (0)
K120
K119
K113
K110
K147
K131
K118
K132
r034
+
-
K100
r033
P315
(0010)
P141
P140
P142
P143
K116 K115
K117
K121
P160 (150,0%)
P161 (-150,0%)
P797
(0011)
K287
P775 (0°)
0.05%
I
0
II
P773
P774
(2111)
P312
K310
K305
P774
(-3,00%)
P773
(0,01%)
P074
(61%)
P076
(002)
P310
(0,15)
P311
(0,015s)
P777
165°
P776
K116
P785 (1)
P776
(150°)
P777
(20,00%)
K102
P312
(2111)
87564321
Sheet 2
P778, P779, Id, Ud, U_netw
(filtering/averaging
and phase correction
of network passages
through zero)
SST2 peer-to-peer, word 5
SST2 peer-to-peer, word 4
SST2 peer-to-peer, word 3
Id control, firing pulse
Ud_setpoint
U netw> P074
Control word, bit27
(source selection
with P587)
Actual value average
(average value with
6 sampling values
of the current
firing cycle)
*1) 0... current value
1 ... average of three
2 ... intermittent: average of three
continuous: actual value
*2) K119:= 0 at detected commutation failure,
on return (if K120 > 0)
network voltage failure (if K120 < 0)
K119:= -0,006%, if all conditions are
fulfilled that prevent reg. feedback
on P797=xx1x
Ud//Id control
switchover
(Mester-/Slave-
operation)
P312 (2111)
P component (active)
I component (active)
U_netw_infeed
U_netw_regenerative_feedback
alpha-G
alpha-W
Disable regenerative feedback on:
STW1.Bit12 = 0 (no regen._feedback enable),
Ud > 0,9375*1,35*U_netw_regen._feedback or
Ud > 0,875*1,35*U_netw_regen._feedb. at AUS1,
Ud > 1,35*U_netw_regen._feedback*P318/100%
(if the Ud_set reduction logic demands it),
U_netw_regen._feedback < P074,
precharging (ramp_function ramp acc. P329),
P076=xx1 (motorized operation only)
Lowest neg.
current limit
Temperature model,
limitation to
+/-150%, +136%/-125%
or +100%/-92%
Thyristor
temperature rise
STW1, bit 12
(source
selection
with P572)
Ud (last sampling value)
U_new_regenerative_feedback
Stop I component
I component = 0
Infeed / regenerative feedback / no supply direction
alpha-W-shift
Id at intermittent limit
Current limit
in infeed direction
currrent limit in
regenerative
feedback direction
Control word I2t
Id_set
Setpoint average
Long / short
pulses
Additional
alpha-W-pulse
Selection Id
setpoint for Id control
Logic for
preventing infeed
or regenerative
feedback
*2)
Lowest pos.
current limit
Feedforward control
Id controller
U_contr
Ud
Id
from Sheet 1
R_in
R_regen L_regen
Kp
Tn
Id at intermittent
limit
0 bzw.
-0,006%
|Id|
Id
L_in
Id
Control set
Id
Ud
Id, set
Figure 4.4.2 Id control, firing pulse
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simovert 6SE70 Series and is the answer not in the manual?

Siemens Simovert 6SE70 Series Specifications

General IconGeneral
BrandSiemens
ModelSimovert 6SE70 Series
CategoryDC Drives
LanguageEnglish

Related product manuals