Technical specifications
6.3 Specifications
Power Module PM230 IP55
76 Hardware Installation Manual, 2010-07-02, A5E02923635A AB
Table 6- 3 PM230 Frame Sizes A, 3 AC 380 V … 480 V, ± 10%
Order No. Class A filter
Class B filter
6SL3223-0DE21-1AA0
6SL3223-0DE21-1BA0
6SL3223-0DE21-5AA0
6SL3223-0DE21-5BA0
6SL3223-0DE22-2AA0
6SL3223-0DE22-2BA0
Values based on Low Overload
● LO power
● LO input current
● LO Output current
1,1 kW
3,2 A
3,1 A
1,5 kW
4,2 A
4,1 A
2,2 kW
6,1 A
5,9 A
Values based on High Overload
● HO power
● HO input current
● HO output current
0,75 kW
2,3 A
2,2 A
1,1 kW
3,2 A
3,1 A
1,5 kW
4,2 A
4,1 A
Common values
● Power losses
● Fuse
● Required cooling air flow
● Cross section of line and
motor cable
● Tightening torque for line and
motor cable
● Weight
0,07 kW
10 A
7 l/s
1 … 2,5 mm
2
0,5 Nm
4,3 kg
0,08 kW
10 A
7 l/s
1 … 2,5 mm
2
0,5 Nm
4,3 kg
0,1 kW
10 A
7 l/s
1,5 … 2,5 mm
2
0,5 Nm
4,3 kg
Table 6- 4 PM230 Frame Sizes A, 3 AC 380 V … 480 V, ± 10%
Order No. Class A filter
Class B filter
6SL3223-0DE23-0AA0
6SL3223-0DE23-0BA0
Values based on Low Overload
● LO power
● LO input current
● LO Output current
3 kW
8,0 A
7,7 A
Values based on High Overload
● HO power
● HO input current
● HO output current
2,2 kW
6,1 A
5,9 A
Common values
● Power losses
● Fuse
● Required cooling air flow
● Cross section of line and
motor cable
● Tightening torque for line and
motor cable
● Weight
0,12 kW
10 A
7 l/s
1,5 … 2,5 mm
2
0,5 Nm
4,3 kg