Siemens SINAMICS PERFECT HARMONY GH150 - 9.7.8 Replacing a diode stack; 9.7.8.1 Discharging the snubber circuit capacitor

Siemens SINAMICS PERFECT HARMONY GH150
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.7.8 Replacing a diode stack
9.7.8.1 Discharging the snubber circuit capacitor
WARNING
Danger to life due to electric shock at the snubber circuit capacitors
The snubber circuit capacitors are not always equipped with discharge resistors. The energy
stored in the capacitors is discharged via a diode. Voltages of up to several 1000 V can occur
and cause an electric shock. This can result in death, severe injuries and significant material
damage.
You should always handle the capacitors as if they are charged.
Discharge the snubber circuit capacitors. Short-circuit the snubber circuit capacitors briefly
before you withdraw the diode stack.
Tool required
Socket wrench set
Set of open-ended wrenches
Torque wrench up to 50 Nm
Ratchet with short extension
Ratchet length extension
Side cutters
Short slotted screwdriver, Size 2
Screwdriver, Torx T30
Cable ties
Touch-up pen, e.g., Edding 751.
Maintenance
9.7 Repair
SINAMICS PERFECT HARMONY GH150 6SL3825