EasyManua.ls Logo

Siemens SINAMICS SM120 - Torques; Table 9-2 Tightening Torques in Nm

Siemens SINAMICS SM120
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The following components may be replaced by qualified maintenance and installation
personnel:
Double submodule (gating unit and capacitor bank)
Sensors (for conductivity, pressure, and temperature)
AVT combination modules
Current transformer
Low-voltage components (e.g. anti-condensation heating, fans, contactors)
9.7.3 Torques
The following table contains the default values. If the replacement of a component requires
different torques, they are specified in the associated sections.
Table 9-2 Tightening torques in Nm
Screw type Soft materials S3
1
Hard materials S2
2
Hard materials S1
3
M3 0,8 1,8 1,3
M4 1,8 3,9 3,0
M5 3,0 7,8 6,0
M6 6,0 13,0 10,0
M8 13,0 32,0 25,0
M10 25,0 65,0 50,0
M12 50,0 115,0 88,0
M16 115,0 270,0 215,0
1
Examples of soft materials are Cu, Al, CuZn cable entries, laminate materials, plastics, cast
resin post insulators, press nuts, welding nuts, blind rivet nuts, and cage nuts.
2
Hard materials S2 are materials with friction-enhancing washer components, e.g. a contact
washer.
3
Hard S1 materials include steel, for example.
Maintenance
9.7 Repair
SINAMICS SM120 6SL38855?B
Operating Instructions 12/2015 105