Laying the signal lines (Page 79)
3.6.3 DRIVE-CLiQ interface
Table 3-11 DRIVE-CLiQ interface
Pin Signal name Technical data
1 TXP Transmit data +
2 TXN Transmit data -
3 RXP Receive data +
4 Reserved, do not use  
5 Reserved, do not use  
6 RXN Receive data -
7 Reserved, do not use  
8 Reserved, do not use  
A + (24 V) Power supply
B M (0 V) Electronics ground
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255. 
The maximum DRIVE-CLiQ cable length is 50 m.
Description
3.6 Interfaces
SINAMICS SM120  6SL38855?B