EasyManua.ls Logo

Siemens SINAMICS SM120 - Table 3-6 Power Stack Adapter 4: Electronic Power Supply; Table 3-7 Power Stack Adapter 4: Inverter Unit; Table 3-8 Power Stack Adapter 4: Braking Module; Table 3-9 Power Stack Adapter 4: PSA Link

Siemens SINAMICS SM120
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electronic power supply
Table 3-6 Power Stack Adapter 4: Electronic power supply
Terminal Designation Technical data
1 Electronics ground M Voltage: 24 VDC (-25% to +30%), 18 V to 31.2 V
Power consumption (without DRIVE-CLiQ or digital
outputs): 1 A max.
2 N.C.
3 Electronic power supply P24
Max. connectable cross-section: 2.5 mm²
Type: Screw terminal
Actual value channels
Table 3-7 Power Stack Adapter 4: Inverter unit
Single fiber-optic cable Meaning, actual value acquisition Technical data
X70, X71 Branch currents, phase L1 Fiber-optic cable type:
1 mm plastic optical fiber (POF)
Max. length of fiber-optic cable:
20 m
X72, X73 Branch currents, phase L2
X74, X75 Branch currents, phase L3
X76, X77 Output voltages
X78 to X81 N.C.
Table 3-8 Power Stack Adapter 4: Braking Module
Single fiber-optic cable Meaning, actual value acquisition Technical data
X78 DC-link voltage M-KM Fiber-optic cable type:
1 mm plastic optical fiber (POF)
Max. length of fiber-optic cable:
20 m
X79 DC-link voltage AM-M
X80 DC-link voltage AM-KM
X70 to X77, X81 N.C.
PSA link
Table 3-9 Power Stack Adapter 4: PSA link
Single fiber-optic cable Meaning
X90
(only available when operated with a
Braking Module)
PSA link for direct data exchange between Power Stack
Adapters
X91 to X93 N.C.
Description
3.4 Components
SINAMICS SM120 6SL38855?B