13.Loosen the bolted connection (M8 x 30). Remove the screw (M8 x 16) of the capacitor
bank.
Image 9-9 Removing the double submodule, step 12
14.Withdraw the capacitor bank towards the front.
Installing the double submodule
Execute the steps described in the section "Removing the double submodule" in the reverse
order.
Maintenance
9.7 Repair
SINAMICS SM120 6SL38855?B
112 Operating Instructions 12/2015