The inverter unit has three phases. Each phase comprises two so-called M2C branches. The
six branches of the M2C inverter each consist of identical double submodules connected in
series. The phase of the voltage-source DC link drive is realized employing M2C technology
using submodules connected in series for two branches.
Branch (identical double submodules connected in series)
Double submodule
Bypass switch (optional)
Actual value sensing
Branch reactor
Image 3-1 Block diagram: Motor Module employing M2C technology
Note
Details on the design can be found in the layout diagram.
Description
3.2 Motor Module employing M2C technology
SINAMICS SM120 6SL38855?B
Operating Instructions 12/2015 29