((Siemens Motor Object - Details))
Siemens Motor Data Object, Instance Number: 32D hex
Supported services
Class ● Get Attribute single Instance ● Get Attribute single
● Set Attribute single
Object "32D hex" is only available on the "VECTOR DO = 12" drive object.
Table A-41 Class Attribute
No. Service Type Name
1 get UINT16 Revision
2 get UINT16 Max Instance
3 get UINT16 Num of Instances
Table A-42 Instance Attribute
No.
Service Type Name Value/explanation
2 get, set UINT16 Commissioning
state
p0010 commissioning parameter filter
3 get, set INT16 Motor Type p0300 motor type
6 get, set REAL Rated Current p0305 rated motor current
7 get, set REAL Rated Voltage p0304 rated motor voltage
8 get, set REAL Rated Power p0307 rated motor power
9 get, set REAL Rated Frequency p0310 rated motor frequency
10 get, set REAL Rated Tempera‐
ture
p0605 threshold and temperature value for monitor‐
ing the motor temperature
11 get, set REAL Max Speed p0322 maximum motor speed
12 get, set UINT16 Pole pair number p0314 motor pole pair number
13 get, set REAL Torque Constant p0316 motor torque constant
14 get, set REAL Inertia p0341 motor moment of inertia
15 get, set REAL Base Speed p0311 rated motor speed
19 get, set REAL Cos Phi p0308 rated motor power factor
The instances are assigned using the slot sequence in p0978.
TCP/IP Interface Object, Instance Number: F5 hex
Supported services
Class ● Get Attribute all
● Get Attribute single
Instance ● Get Attribute all
● Get Attribute single
● Set Attribute single
Communication
A.1 Communication
Industrial Security
Configuration Manual, 08/2017, A5E36912609A 197