Table A-43 Class Attribute
No. Service Type Name
1 get UINT16 Revision
2 get UINT16 Max Instance
3 get UINT16 Num of Instances
Table A-44 Instance Attribute
No. Service Type Name Value/explanation
1 get UNIT32 Status Fixed value: 1 hex
1: Configuration acknowledged, by DHCP or saved
values
2 get UNIT32 Configuration Ca‐
pability
Fixed value: 94 hex
4 hex: DHCP supported,
10 hex: Configuration can be adjusted,
80 hex: ACD-capable
3 get, set UNIT32 Configuration
Control
1 hex: Saved values
3 hex: DHCP
4 get UNIT16 Physical Link Path Size (in WORDs)
Fixed value: 2 hex
UNIT8 Path
20 hex,
F6 hex,
24 hex,
05 hex, where 5 hex is the number of instances of
F6 hex (four physical ports plus one internal port).
5 get, set STRING Interface Configu‐
ration
r61000 Name of Station
UNIT32 r61001 IP address
6 get, set UNIT16 Host Name Host Name Length
STRING ‑
10 get, set UNIT8 Select ACD local OM flash:
0: Disabled,
1: Enabled
11 get, set UNIT8 Last Conflict De‐
tected
local OM flash ACD Activity
UNIT8 local OM flash Remote MAC
UNIT8 local OM flash ARP PDU
Link Object, Instance Number: F6 hex
Supported services
Class ● Get Attribute all
● Get Attribute single
Instance ● Get Attribute all
● Get Attribute single
● Set Attribute single
Communication
A.1 Communication
Industrial Security
198 Configuration Manual, 08/2017, A5E36912609A