EasyManua.ls Logo

Siemens Sinumerik 801 - Page 25

Siemens Sinumerik 801
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Start-Up
SINUMERIK 801 2-9
Start-Up
Notice
Bracketed dimensions as shown in the figure above are suitable for
STEPDRIVE C
+
.
The modules should be installed such that a clearance of at least 10 cm is left
above, below and between the modules (dimension “a”).
The drive modules, however, can be mounted directly side by side (a>10 mm)
provided they are ventilated with an air stream greater than / equal to 1 m/s.
Do not install devices which are strongly heated during operation beneath the
drive modules!
Step motors
Fig. 2-9 Dimensions of the stepper motors (see Table 2-1)
Table 2-1 Outline dimensions of the stepper motors (see Fig. 2-9)
Dimensions and tolerance
Model
D D1 D2 D3 D4 D5 L L
1
L
2
L
3
L
4
h h1 A B C
Key
Wt.
(kg)
6FC5
548-0AB03-
0AA0
92 9f6 10 60f7 107 6.6 162 34 14 20 26 3 7 93 62.5 R10
C3X1
4
3
6FC5
548-0AB06-
0AA0
110 16f6 17 56f7 127 8.5 186.5 34 25 32 37 2 12.5 112 65.0
10X4
5
°
C5X2
5
5.6
6FC5
548-0AB09-
0AA0
110 16f6 17 56f7 127 8.5 216.5 34 25 32 37 2 12.5 112 65.0
10X4
5
°
C5X2
5
7.2
6FC5
548-0AB12-
0AA0
110 16f6 17 56f7 127 8.5 248.5 34 25 32 37 2 12.5 112 65.0
10X4
5
°
C5X2
5
8.6
6FC5
548-0AB18-
0AA0
130 16f6
17h
7
100f7 155 10.5 239.0 34 32 36 43 3 15.0 132 90.0
10X4
5
°
C5X2
5
13.0
6FC5
548-0AB25-
0AA0
130 16f6
17h
7
100f7 155 10.5 263.5 34 32 36 43 3 15.0 132 90.0
10X4
5
°
C5X2
5
15.0
When installing the stepper motor, its radial load shall stay within the data
range listed below: