Start-Up
SINUMERIK 801 2-9
Start-Up
Notice
Bracketed dimensions as shown in the figure above are suitable for
STEPDRIVE C
+
.
The modules should be installed such that a clearance of at least 10 cm is left
above, below and between the modules (dimension “a”).
The drive modules, however, can be mounted directly side by side (a>10 mm)
provided they are ventilated with an air stream greater than / equal to 1 m/s.
Do not install devices which are strongly heated during operation beneath the
drive modules!
Step motors
Fig. 2-9 Dimensions of the stepper motors (see Table 2-1)
Table 2-1 Outline dimensions of the stepper motors (see Fig. 2-9)
Dimensions and tolerance
Model
D D1 D2 D3 D4 D5 L L
1
L
2
L
3
L
4
h h1 A B C
Key
Wt.
(kg)
6FC5
548-0AB03-
0AA0
92 9f6 10 60f7 107 6.6 162 34 14 20 26 3 7 93 62.5 R10
C3X1
4
3
6FC5
548-0AB06-
0AA0
110 16f6 17 56f7 127 8.5 186.5 34 25 32 37 2 12.5 112 65.0
10X4
5
°
C5X2
5
5.6
6FC5
548-0AB09-
0AA0
110 16f6 17 56f7 127 8.5 216.5 34 25 32 37 2 12.5 112 65.0
10X4
5
°
C5X2
5
7.2
6FC5
548-0AB12-
0AA0
110 16f6 17 56f7 127 8.5 248.5 34 25 32 37 2 12.5 112 65.0
10X4
5
°
C5X2
5
8.6
6FC5
548-0AB18-
0AA0
130 16f6
17h
7
100f7 155 10.5 239.0 34 32 36 43 3 15.0 132 90.0
10X4
5
°
C5X2
5
13.0
6FC5
548-0AB25-
0AA0
130 16f6
17h
7
100f7 155 10.5 263.5 34 32 36 43 3 15.0 132 90.0
10X4
5
°
C5X2
5
15.0
When installing the stepper motor, its radial load shall stay within the data
range listed below: