EasyManuals Logo

Siemens SINUMERIK 804D sl Commissioning Manual

Siemens SINUMERIK 804D sl
1734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1177 background imageLoading...
Page #1177 background image
//M(TimerSample/"My timer")
VS2=("Stop%ntimer")
SUB(MyTimerSub)
MyVariable = MyVariable + 1
END_SUB
PRESS(VS1)
;Calls SUB "MyTimerSub" every 1000 milliseconds
START_TIMER("MyTimerSub", 1000)
END_PRESS
PRESS(VS2)
STOP_TIMER("MyTimerSub")
END_PRESS
If START_TIMER is called again for a timer already assigned to a SUB method, then the new
interval is taken over if it is different. Otherwise, the second call is ignored.
The smallest interval for the system is100 milliseconds.
If STOP_TIMER is called for a SUB method for which no timer is currently running, the call is
ignored.
Programming commands
6.3 Functions
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 191

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals