ScaleTextEmbedded - position of the scaling texts
Syntax: ReturnValue = ReadCWProperty
(GraphVarName, "
ScaleTextEmbedded
")
WriteCWProperty
(GraphVarName, "
ScaleTextEmbedded
", Value)
Description: Using this property you define whether the scaling is positioned inside or outside
the drawing area.
Parameters: GraphVarName Name of the display variable which contains a SlEs‐
GraphCustomWidget
Return Value Read value of the property (bool)
Value Value to be set (bool): TRUE or FALSE
Example
Scaling text outside the drawing area:
ScaleTextEmbedded = FALSE
Figure 7-3 Scaling text outside the drawing area
Scaling text within the drawing area:
ScaleTextEmbedded = TRUE
Figure 7-4 Scaling text within the drawing area:
Graphic and logic elements
7.5 SIEsGraphCustomWidget
SINUMERIK Integrate Run MyScreens (BE2)