EasyManuals Logo

Siemens SINUMERIK 804D sl Commissioning Manual

Siemens SINUMERIK 804D sl
1734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #208 background imageLoading...
Page #208 background image
Example 2
Entries Meaning
Assign new cutting edge parameter name
The name is "EdgeUser_1_Bit0" in the following example.
Base Name of the parameter on which the new parameter is based.
In the following example, the "EdgeUser_1" parameter is used as template.
Also enter only the changed data here. All other data is taken from the existing
cutting edge parameter.
The following entries are changed:
Field type: Input/output field for states
Value output: All characters
Bit mask: Bit 0
Column width changed to 17 pixels.
Header changed to "TM_HL_EDGE_USER_1_Bit0"
Text in the tooltip changed to "TM_TT_EDGE_USER_1_Bit0"
<PARAMETERCONFIGURATION>
<EdgeUser_1_Bit0>
<Base value="EdgeUser_1" type="QString" />
<ItemType value="CheckBox" type="QString" />
<DisplayMode value="AnyMode" type="QString" />
<BitMask value="1" type="int" />
<Width value="17" type="int" />
<HeadLine value="TM_HL_EDGE_USER_1_Bit0" type="QString" />
<ToolTip value="TM_TT_EDGE_USER_1_Bit0" type="QString" />
</EdgeUser_1_Bit0>
</PARAMETERCONFIGURATION>
Tool management
12.2 Configuring the user interface
SINUMERIK Operate (IM9)
194 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals