Page #301 background imageLoading...
Page #301 background image
You can copy this area from the original file. The "slaesvcadapconf.xml" file is in the following
directory: /siemens/sinumerik/hmi/base
Setting
In the <MissingTextWarning type="bool" value="FALSE"/> tag, deactivate/activate the
warning.
Entry Meaning
TRUE The warning is displayed.
FALSE The warning is deactivated.
Example
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<CONFIGURATION>
<ControlFlags>
<MissingTextWarning type="bool" value="FALSE"/>
</ControlFlags>
</CONFIGURATION>
Configuring alarms
13.5 Deactivating a warning
SINUMERIK Operate (IM9)