Detailed description
2.12 Block descriptions
Power Line Basic PLC Program (P3)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-141
Digitizing on (DIGION)
Function:
Selecting digitizing in the specified channel
Parameterization:
Signal Type Value range Meaning
PIService ANY PI.DIGION Digitizing on
Unit INT 1 to 10 Channel
Digitizing OFF (DIGIOF)
Function:
Deactivating digitizing in the specified channel
Parameterization:
Signal Type Value range Meaning
PIService ANY PI.DIGIOF Digitizing off
Unit INT 1 to 10 Channel
Initiate NC Reset
NCRES
Function:
Initiates an NCK Reset. The Unit and WVar1 parameters must be assigned 0.
Parameterization:
Signal Type Value range Meaning
PIService ANY PI.NCRES Initiate NC Reset
Unit INT 0 0
WVar1 WORD 0 0