Detailed Description
2.12 Block descriptions
PLC Basic Program Solution Line (P3 sl)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-227
Note
The number of user areas can be parameterized via FB 1.
After the configuration has been modified (FB 1: MsgUser), DB 2/3 must be deleted.
Channel areas in DB 2
Area Address Message number
Channel 1 DBX0.0 - DBX11.7 510.000 -- 510.231
Channel 1, geo axes DBX12.0 - DBX17.7 511.100 - 511.315
Channel 2 DBX18.0 - DBX29.7 520.000 - 520.231
Channel 2, geo axes DBX30.0 - DBX35.7 521.100 - 521.315
Channel 3 DBX36.0 - DBX47.7 530.000 - 530.231
Channel 3, geo axes DBX48.0 - DBX53.7 531.000 - 531.315
Channel 4 DBX54.0 - DBX65.7 540.000 - 540.231
Channel 4, geo axes DBX66.0 - DBX71.7 541.100 - 541.315
Channel 5 DBX72.0 - DBX83.7 550.000 - 550.231
Channel 5, geo axes DBX84.0 - DBX89.7 551.100 - 551.315
Channel 6 DBX90.0 - DBX101.7 560.000 - 560.231
Channel 6, geo axes DBX102.0 - DBX107.7 561.100 - 561.315
Channel 7 DBX108.0 - DBX119.7 570.000 - 570.231
Channel 7, geo axes DBX120.0 - DBX125.7 570.100 - 571.315
Channel 8 DBX126.0 - DBX137.7 580.000 - 580.231
Channel 8, geo axes DBX138.0 - DBX143.7 581.100 - 581.315
Channels 9 and 10 are not currently
implemented
User areas in DB 2
Area Address Message number
Axis/spindle 1 DBX144.0 - DBX145.7 600.100 - 600.115
Axis/spindle 2 DBX146.0 - DBX147.7 600.200 - 600.215
Axis/spindle 3 DBX148.0 - DBX149.7 600.300 - 600.315
Axis/spindle 4 DBX150.0 - DBX151.7 600.400 - 600.415
Axis/spindle 5 DBX152.0 - DBX153.7 600.500 - 600.515
Axis/spindle 6 DBX154.0 - DBX155.7 600.600 - 600.615
Axis/spindle 7 DBX156.0 - DBX157.7 600.700 - 600.715
Axis/spindle 8 DBX158.0 - DBX159.7 600.800 - 600.815
Axis/spindle 9 DBX160.0 - DBX161.7 600.900 - 600.915
Axis/spindle 10 DBX162.0 - DBX163.7 601.000 - 601.015