Detailed Description
2.4 Closed-loop control
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-51
The type of fine interpolation can be defined via machine data:
MD33000 $MA_FIPO_TYPE (fine interpolation type).
A differential FIPO not only performs cycle matching but also calculates a mean value
(smoothing) from an IPO cycle.
The cubic FIPO, type 3, supplies the best contour accuracy in addition to the cycle
adaptation.
K
v
factor
To ensure that only low contour deviations occur in continuous-path mode,
a high servo gain factor (K
v
):
MD32200 $MA_POSCTRL_GAIN[n]
is required.
However, if the servo gain factor (K
v
) is too high, instability, overshoot and possibly
impermissibly high loads on the machine will result.
The maximum permissible servo gain factor (K
v
) depends on the following:
Design and dynamics of the drive
(rise time, acceleration and braking capacity)
Machine quality
(elasticity, oscillation damping)
Position-control cycle
The servo gain factor (K
v
) is defined as follows:
9HORFLW\
)ROORZLQJHUURU
>PPLQ@
.9
>PP@
[m/min]/[mm]: Unit of servo gain factor (K
V
) according to VDI standard

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals