8.4 DMP compact module 1I analog (6FC5111-0CA04-0AA0)
8-105
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
Analog voltage measurement
UU
Measurement with PT100
Differential input
(common-mode
disturbances are
suppressed)
Unipolar
(default)
PT100 with
4-wire connection
PT100 with
2-wire
connection
S
6
M
5
4
+
32
S
1
X2
S
6
M
5
4
+
32
S
1
X2
S
6
M
5
4
+
3
S
1
X2
S
6
M
5
4
+
3
I
2
S
1
X2
I
2
Fig. 8-5 Example circuits for DMP compact module 1I analog
Note
If the power source is not required, it must be short-circuited.
Table 8-6 Technical data DMP compact module 1I analog
Number of inputs 1 analog input
Galvanic isolation Yes
Power supply V
LOAD
Rated value 24 V DC
Perm. range 20.4 V to 28.8 V
Ripple 3.6 Vpp
Input voltage Rated range
"10 V or "500 mV+
Overshoot range
"20 V or "1 V
Current consumption (24 V) 45 mA
I
const
for PT100 2.5 mA
Connection of signal generators see below
Digital representation of the input signal 12 bits + sign
Error message (input voltage in the overshoot range) Yes
Basic error limits
"0.2 %
Operational limits (0
C to 60
C)
"0.5 %
Length of cables (shielded) max. 30 m
Weight about 150 g
Example
circuits
8 DMP Com
p
act Modules

Related product manuals